Feld-Messkampagne Partikelemissionen aus Holzfeuerungen
Résumé
Phase 2 zusammen mit BUWAL 50%/50%
Textes supplémentaires
Schlussbericht
Wood combustion processes produce smoke emissions, which are of concern to authorities and the public. Recent European studies claim airborne particulate matter (PM) smaller than 10 mm (PM10) as major respiratory irritants (Air pollution and Health, EC-APHEA I and II). The Swiss Federal Environmental Protection Agency (BUWAL) requires emission factors on PM pollutants of various sources in order to establish strategies for aerosol abatement. The work carried out by the Center of Appropriate Technology and Social Ecology covered the investigations of typical wood fuel combustion systems in the field under real world conditions. This to cope with the lack of quantified PM emission factors and characterization in terms of particle number and size distribution.Two analytical methods were used to monitor PM emissions. A Scanning Mobility Particle Sizer (SMPS) was utilized to determine nanoparticle numbers and size distribution in wood combustion stack gases with a mobility diameter from 0.015 up to 0.6 mm (PM0.6). Total Suspended Particles (TSP) were measured simultaneously to compare TSP with the emissions of PM0.6, calculated from the SMPS-analysis.Totally 14 different wood combustion systems were tested including room heating appliances, wood log and automatic fed boilers. The wood based fuel comprised logs, chips and pellets. It could be shown that the major part of the particle sizes is in the range of 30 to 300 nm. Particles coarser than 300 nm do not add substantially to the total emission rate in the flue gases. The particle distribution of manual operated appliances is quite varying during a burn cycle, while wood log and continuous fed boilers show a fairly constant particle size distribution. In each category there have been found low emission equipment. The minimum emission factor of total particle number of the different combustion systems was found in the range of approximately 1:3.8, where as the maximum was widely spread. The TSP emission factors correspond fairly well with the figures calculated from SMPS data as PM0.6 mass based emission factors, if there were little products of incomplete combustion (PIC) and no high grate vent entraining ash particles. The data resulting from these investigations allow prediction of the PM on a particular airshed of a population of different wood combustion systems.For comparison there have been tested several fossil fueled boilers and co-generation plants. The average PM0.6 emission factor is of a factor 16 lower than the one in wood stack gases.Keywords: wood combustion, biomass, particulate matter, emission factor, field measurement, fossil fuelEinleitung1.1 AusgangslageNeuste Ergebnisse der europäischen Studie über die Auswirkungen der Luftverschmutzung auf die Gesundheit, APHEA (Air pollution and health), zeigen, dass Feinstaub im Mikron- und Submikronbereich (Partikeldurchmesser dp Auftragnehmer/Contractant/Contraente/Contractor: Ökozentrum Langenbruck ÖZL Autorschaft/Auteurs/Autori/Authors: Gaegauf,Christian Macquat,Yves Wieser,Ulrich
Publikationen / Ergebnisse
Partikel gelten als wichtiger Luftbelastungsfaktor. In der Schweiz stammen ca. 44 % der Partikelemissionen im Mikron- und Submikronbereich (Partikeldurchmesser Auftragnehmer/Contractant/Contraente/Contractor: Ökozentrum Langenbruck ÖZL Autorschaft/Auteurs/Autori/Authors: Gaegauf,Christian Macquat,Yves Wieser,Ulrich
Schlüsselwörter
TP0070;F-Holz
Détails du projet
- Office de recherche
- BFE
- Statut du projet
- Abgeschlossen
- Type de projet
- Forschungsprojekt
- Date de début
- 2000-05-31
- Date de fin
- 2002-04-29
- Coûts totaux approuvés
- CHF 60000.00
- Section
- Holzenergie
- Domaine politique NABS
- Erzeugung, Verteilung und rationelle Nutzung der Energie
Labels
Disciplines de recherche
- T140 Energy research 100.0%